{"id":4642,"date":"2025-09-22T10:09:15","date_gmt":"2025-09-22T08:09:15","guid":{"rendered":"https:\/\/decker-vt.de\/regenerate-ion-exchangers\/"},"modified":"2026-01-20T09:21:04","modified_gmt":"2026-01-20T08:21:04","slug":"ion-exchanger-regeneration","status":"publish","type":"page","link":"https:\/\/decker-vt.de\/en\/services\/ion-exchanger-regeneration\/","title":{"rendered":"Regenerate ion exchangers"},"content":{"rendered":"\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained gs_3J9yTu group_wrap\">\n<h1 class=\"wp-block-heading\">Regenerate ion exchangers<\/h1>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-tertiary-background-color has-background has-global-padding is-layout-constrained wp-block-group-is-layout-constrained gs_KGByWy group_wrap\">\n<div id=\"greyd-69d4486475c98\" class=\"wp-block-greyd-box aligncenter gs_IWHy9X greyd-content-box gs_IWHy9X flex-justify-center\">\n<h2 class=\"wp-block-heading\">Ion exchanger regeneration<\/h2>\n\n\n\n<p><strong>Ion exchanger regeneration as a service includes the external regeneration of ion exchangers or ion exchanger cartridges \/ a demineralization cartridge a.o. from applications such as UPW or demineralized water production, semiconductors, circulation of rinsing water, groundwater remediation and selective removal of heavy metals e.g. copper, nickel, chromium (selective exchanger resin) in an industrial plant.<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"margin-top:var(--wp--preset--spacing--large)\"><div  class=\"gs_USez4a alignwide\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-04293b2c wp-block-columns-is-layout-flex\" style=\"padding-right:0;padding-left:0\">\n<div class=\"wp-block-column col-12 col-sm-12 col-md-6 col-lg-6 is-layout-flow wp-block-column-is-layout-flow\"><figure style=\"padding-top:0;padding-bottom:0;margin-bottom:var(--wp--preset--spacing--tiny);\" class=\"wp-block-image greyd-image  aligncenter gs_CwWrJu\"><img loading=\"lazy\" decoding=\"async\" width=\"874\" height=\"583\" src=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/09\/Regeneration-Anschlauchen.jpg\" class=\"wp-image-4544\" alt=\"Regeneration-Anschlauchen\" srcset=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/09\/Regeneration-Anschlauchen.jpg 874w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/09\/Regeneration-Anschlauchen-300x200.jpg 300w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/09\/Regeneration-Anschlauchen-768x512.jpg 768w\" sizes=\"auto, (max-width: 874px) 100vw, 874px\" \/><\/figure>\n\n<figure style=\"padding-top:0;margin-top:0;\" class=\"wp-block-image greyd-image  aligncenter gs_0aE6Zn\"><img loading=\"lazy\" decoding=\"async\" width=\"844\" height=\"563\" src=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Nachbehandlung-von-Ionenaustauscherregeneraten.jpg\" class=\"wp-image-4644\" alt=\"Nachbehandlung-von-Ionenaustauscherregeneraten\" srcset=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Nachbehandlung-von-Ionenaustauscherregeneraten.jpg 844w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Nachbehandlung-von-Ionenaustauscherregeneraten-300x200.jpg 300w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Nachbehandlung-von-Ionenaustauscherregeneraten-768x512.jpg 768w\" sizes=\"auto, (max-width: 844px) 100vw, 844px\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-column col-12 col-sm-12 col-md-auto col-lg-auto is-layout-flow wp-block-column-is-layout-flow\"><figure style=\"padding-top:0;margin-bottom:var(--wp--preset--spacing--tiny);\" class=\"wp-block-image greyd-image  aligncenter gs_rfekN3\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-Mischbettanlage-quad-1024x1024.jpg\" class=\"wp-image-4643\" alt=\"Regeneration-Mischbettanlage-quad\" srcset=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-Mischbettanlage-quad-1024x1024.jpg 1024w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-Mischbettanlage-quad-300x300.jpg 300w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-Mischbettanlage-quad-150x150.jpg 150w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-Mischbettanlage-quad-768x768.jpg 768w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-Mischbettanlage-quad.jpg 1089w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<figure style=\"padding-top:0;margin-bottom:0;margin-top:0;\" class=\"wp-block-image greyd-image  aligncenter gs_bgFEvz\"><img loading=\"lazy\" decoding=\"async\" width=\"804\" height=\"536\" src=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-extern-zu-regenerierenden-Ionenaustauscherpatronen.jpg\" class=\"wp-image-4645\" alt=\"Regeneration-von-extern-zu-regenerierenden-Ionenaustauscherpatronen\" srcset=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-extern-zu-regenerierenden-Ionenaustauscherpatronen.jpg 804w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-extern-zu-regenerierenden-Ionenaustauscherpatronen-300x200.jpg 300w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-extern-zu-regenerierenden-Ionenaustauscherpatronen-768x512.jpg 768w\" sizes=\"auto, (max-width: 804px) 100vw, 804px\" \/><\/figure><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Regenerate and condition ion exchangers (or ion exchanger resin or ion exchanger cartridges)<\/h2>\n\n\n\n<p><a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchangers\/\">Ion exchangers<\/a> in <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchanger-system\/\">ion exchanger cartridges<\/a> (e.g. externally regenerated <a href=\"https:\/\/decker-vt.de\/en\/products\/selective-ion-exchanger-system\/\">selective exchangers<\/a> or a <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">demineralization cartridge <\/a>or <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">demineralization cartridge<\/a>) are similar to filters in their effect. The ion exchangers are charged by substances dissolved in the water as long as there is still sufficient capacity. An exchange takes place against the ions present on the ion exchanger (from the delivery form, regeneration or activation) in accordance with the selectivity series. Ions (already bound) that have a lower selectivity compared to the ion exchanger resin and are therefore bound more weakly are displaced by ions with a higher affinity from the head groups of the ion exchanger resin and enter the outlet of the ion exchanger. This exchange process takes place continuously until loading is stopped and the resins are returned to their original state by means of regeneration, i.e. they are regenerated with chemicals in excess. During the regeneration of ion exchangers, the ions previously bound in the process are released from the ion exchanger and the exchanger is returned to its original operational state.<\/p>\n\n\n\n<p>This regeneration process differs depending on the ion exchanger used and the application in which the ion exchanger resin is used (e.g. <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">demineralization cartridge \/ VE-cartridge<\/a> or <a href=\"https:\/\/decker-vt.de\/en\/products\/selective-ion-exchanger-system\/\">selective exchanger<\/a> or <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchanger-system\/\">circulation ion exchanger<\/a>). Cation exchangers, i.e. sulphonic acid exchangers (SAC) and carboxylic acid exchangers (WAC), are usually regenerated with an acid. Weakly and strongly basic anion exchangers, i.e. teritary amine exchangers (WBA) and quaternary amine exchangers (SBA), are usually regenerated with an alkaline solution. Selective exchangers, so-called IDE exchangers (iminodiacetic acid exchangers), are regenerated with acid like cation exchangers. Special exchangers such as thiourea exchangers or bispicolyanimine exchangers require special treatment.<\/p>\n\n\n\n<p>As part of the regeneration of ion exchangers, the bound substances are eluted from the ion exchanger, e.g. the hardness formers Ca\/Mg or the heavy metals Ni, Cr(III)\/(VI), Cu, Zn, Pb. The various ion exchangers are then converted into the desired form, known as activation. Cation exchangers are usually converted into the H+, Na+, Ca+, K+ form or protonated ammonium form (NH4), anion exchangers usually into the OH-, Cl- or NH3- form. The process takes place entirely in a WHG safety zone, the eluted substances are treated in the company\u2019s own wastewater treatment plant CP according to the state of the art.   <\/p>\n\n\n\n<p>The regeneration of ion exchangers is a service that requires extensive individual steps, depending on the requirements of the resin, the loading and the pre-cleaning process. To ensure success, a considerable amount of equipment is required to supply the necessary media, such as various acids, alkalis, activation chemicals, compressed air, vacuum, sterilized DI-water &lt; 0.1 \u00b5S\/cm and city water.  <\/p>\n\n\n\n<p>Some new resin types require either a special form for their use that differs from the delivery form, such as standard selective exchangers, which regularly have higher capacities and lower slip in the mono-sodium form. Other exchangers, such as strongly basic type I anion exchangers, require <a href=\"https:\/\/decker-vt.de\/en\/ion-exchanger-fish-odour\/\">pre-cleaning<\/a> to remove production-related impurities before they can be used. <\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-greyd-accordion gs_8Hvgp0 hasiconleft\" data-autoclose=\"true\" data-openfirst=\"false\" style=\"margin-top:0;margin-bottom:0;padding-top:0;padding-bottom:0\">\n<div class=\"wp-block-greyd-accordion-item\"><button class=\"wp-block-greyd-accordion__title\" role=\"button\" type=\"button\" aria-expanded=\"false\" aria-controls=\"sect-nhwk-2\" id=\"title-nhwk-2\"><span><strong><br>Regeneration of mixed bed resin or VE cartridges (demineralization cartridges)<\/strong><\/span><span class=\"icon icon-normal arrow_carrot-down\" aria-hidden=\"true\"><\/span><span class=\"icon icon-active arrow_carrot-up\" aria-hidden=\"true\"><\/span><\/button><div class=\"wp-block-greyd-accordion__content\" role=\"region\" id=\"sect-nhwk-2\" aria-labelledby=\"title-nhwk-2\" hidden>\n<p>So-called mixed bed resins (e.g. from a <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">demineralization cartridge \/ demineralization cartridge<\/a>) with a mixture of cation and anion resins are first separated from each other in a separation column for <a href=\"https:\/\/decker-vt.de\/en\/demineralization-cartridge-exhausted\/\">mixed bed resin regeneration<\/a> when the <a href=\"https:\/\/decker-vt.de\/en\/regenerate-mixed-bed-resin\/\">demineralization cartridge<\/a> is exhausted, then transferred (regenerated) to the H+ or OH- form in separate containers and finally homogenized again in the initial mixing ratio as mixed bed resin. If no proprietary regeneration or closed-pool has been agreed, this results in a mixture of different resins and customer applications. Regeneration should take place as soon as the outlet conductivity rises for the first time, otherwise the <a href=\"https:\/\/decker-vt.de\/vollentsalzungspatrone-ueberfahren\/\">demineralization cartridge will be overrun<\/a>.<\/p>\n\n\n\n<p>In principle, any ion exchanger or <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchangers\/\">ion exchanger<\/a> cartridge can be regenerated, including UPW mixed bed resins, e.g. for semiconductor production with rinsing, e.g. up to &lt;&lt;0.08 \u00b5S\/cm. However, depending on the loading, an extremely strong bond between the head group and the adsorbate can make it almost impossible to remove the bound substance. In this case, it is an actual single-use application due to the preliminary process.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-greyd-accordion-item\"><button class=\"wp-block-greyd-accordion__title\" role=\"button\" type=\"button\" aria-expanded=\"false\" aria-controls=\"sect-znzk-3\" id=\"title-znzk-3\"><span><strong>Organizational procedure for ion exchanger regeneration<\/strong><\/span><span class=\"icon icon-normal arrow_carrot-down\" aria-hidden=\"true\"><\/span><span class=\"icon icon-active arrow_carrot-up\" aria-hidden=\"true\"><\/span><\/button><div class=\"wp-block-greyd-accordion__content\" role=\"region\" id=\"sect-znzk-3\" aria-labelledby=\"title-znzk-3\" hidden>\n<p>As part of the commissioning phase, the technical parameters of the respective process are first validated for general suitability for regeneration (e.g. loading process, any interfering loads such as mineral oils, precipitation, blockages). After ordering the regeneration of ion exchangers, a phone call or a delivery bill is sufficient to place the individual order, depending on the agreement. The loaded ion exchanger, i.e. <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchanger-system\/\">ion exchanger cartridg<\/a>e or <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">demineralization cartridge<\/a>, is disconnected from the system and drained of residual water (e.g. using compressed air &lt;0.5 bar). Instead of the removed cartridge, the 2nd cartridge therefore switches to the first position and an optional additional cartridge takes the place of the 2nd cartridge. The <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchanger-system\/\" data-type=\"link\" data-id=\"https:\/\/decker-vt.de\/produkte\/ionenaustauscheranlage\/\">ion exchanger cartridge<\/a> that has been emptied of residual water is now sent to the <a href=\"https:\/\/goo.gl\/maps\/JrcxyEhbhzrszKWp8\" data-type=\"link\" data-id=\"https:\/\/goo.gl\/maps\/JrcxyEhbhzrszKWp8\" target=\"_blank\" rel=\"noopener\">central regeneration station<\/a> for <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchangers\/\" data-type=\"link\" data-id=\"https:\/\/decker-vt.de\/produkte\/ionenaustauscher\/\">ion exchangers<\/a> in 92348 Berg either via one of our tours or by a forwarding agent. Regeneration usually takes place within 14 days, in the case of urgent regenerations within 1-2 working days by arrangement. Depending on the agreement, the ion exchanger cartridge is then delivered again on the next tour or sent by a forwarding agent or the customer\u2019s own forwarding agent is informed that it is ready for dispatch. If the ion exchanger can no longer be regenerated due to age, loading, contamination or similar, <a href=\"https:\/\/decker-vt.de\/wechsel-ionenaustauscher\/\">the ion exchanger will be replaced<\/a> (resin replacement) after consultation.       <\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-greyd-accordion-item\"><button class=\"wp-block-greyd-accordion__title\" role=\"button\" type=\"button\" aria-expanded=\"false\" aria-controls=\"sect-znzk-4\" id=\"title-znzk-4\"><span><strong>Polisher mixed bed resins for ultrapure water production<\/strong><\/span><span class=\"icon icon-normal arrow_carrot-down\" aria-hidden=\"true\"><\/span><span class=\"icon icon-active arrow_carrot-up\" aria-hidden=\"true\"><\/span><\/button><div class=\"wp-block-greyd-accordion__content\" role=\"region\" id=\"sect-znzk-4\" aria-labelledby=\"title-znzk-4\" hidden>\n<p>Polisher mixed bed resins or Ultra Pure Water (UPW) mixed bed exchangers are ion exchangers that are used for the fine purification of demineralized water in ultrapure water production, e.g. after <a href=\"https:\/\/decker-vt.de\/en\/products\/electrodeionization\/\">electrodeionization.<\/a> These are generally higher quality resins that have a higher capacity and better binding behavior towards residual contamination in demineralized water.<\/p>\n\n\n\n<p>As a rule, this is a closed-pool or proprietary regeneration of the ion exchanger mixed bed resins, as no mixing with other customers is desired here. On the one hand, this would reduce the quality of the resins, and on the other hand, this is the only way to monitor the resin quality over the service life of the ion exchangers over the years. <\/p>\n\n\n\n<p>So-called non-regenerable disposable mixed-bed resins are also frequently used to ensure consistent quality. However, these resins, which are labeled as non-regenerable, can also be regenerated in a special process and retain their consistent quality. <\/p>\n<\/div><\/div>\n<style class=\"greyd-styles\">.gs_8Hvgp0 .wp-block-greyd-accordion-item { --accord-title-bg-color: var(--wp--preset--color--tertiary); --accord-title-text-color: var(--wp--preset--color--secondary); --accord-bg-color: var(--wp--preset--color--tertiary); --accord-text-color: var(--wp--preset--color--foreground); --accord-icon-font-size: 1.8em; --accord-title-font-size: 1.3em; --accord-content-margin-bottom: 0px; --accord-padding: 0 0 1rem 0; --accord-content-padding: 0px 0 0 0; --accord-transition-duration: 1.2s; } .gs_8Hvgp0 .wp-block-greyd-accordion-item:hover { --accord-title-text-color: var(--wp--preset--color--primary); } .gs_8Hvgp0 .wp-block-greyd-accordion-item :checked + * { --accord-title-text-color: var(--wp--preset--color--primary); --accord-text-color: var(--wp--preset--color--secondary); --accord-bg-color: var(--wp--preset--color--tertiary); } <\/style><style class=\"greyd-styles\">. { --accord-title-bg-color: var(--wp--preset--color--tertiary); --accord-title-text-color: var(--wp--preset--color--secondary); --accord-bg-color: var(--wp--preset--color--tertiary); --accord-text-color: var(--wp--preset--color--foreground); --accord-icon-font-size: 1.8em; --accord-title-font-size: 1.3em; --accord-content-margin-bottom: 0px; --accord-padding: 0 0 1rem 0; --accord-content-padding: 0px 0 0 0; --accord-transition-duration: 1.2s; } .:hover { --accord-title-text-color: var(--wp--preset--color--primary); } .gs_8Hvgp0 .wp-block-greyd-accordion__title[aria-expanded=\"true\"] { --accord-title-text-color: var(--wp--preset--color--primary); --accord-text-color: var(--wp--preset--color--secondary); --accord-bg-color: var(--wp--preset--color--tertiary); } <\/style><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column col-12 col-sm-auto is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\" style=\"margin-top:var(--wp--preset--spacing--large);margin-bottom:var(--wp--preset--spacing--large)\"><img loading=\"lazy\" decoding=\"async\" width=\"775\" height=\"614\" src=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-UPW-Mischbettharz-Halbleiter.jpg\" alt=\"\" class=\"wp-image-4494\" srcset=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-UPW-Mischbettharz-Halbleiter.jpg 775w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-UPW-Mischbettharz-Halbleiter-300x238.jpg 300w, https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-UPW-Mischbettharz-Halbleiter-768x608.jpg 768w\" sizes=\"auto, (max-width: 775px) 100vw, 775px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p><a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchangers\/\">Ion exchanger <\/a>regeneration takes place under optimum process conditions<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Regeneration of ion exchanger <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">demineralization cartridge<\/a> \/ <a href=\"https:\/\/decker-vt.de\/en\/products\/demineralization-cartridge-ve-cartridge\/\">VE-cartridge<\/a> or <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchangers\/\">mixed bed resin<\/a> (&lt;0.1 \u00b5S\/cm) or UPW mixed bed resins (&lt;0.08 \u00b5S\/cm) from ultrapure water production (e.g. mixed bed polisher ion exchanger after <a href=\"https:\/\/decker-vt.de\/en\/products\/electrodeionization\/\">electrodeionization<\/a>) as closed-pool regeneration.<\/li>\n\n\n\n<li>Regeneration of heavy metal, chromate or cyanide loaded <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchanger-system\/\">ion exchangers<\/a> or <a href=\"https:\/\/decker-vt.de\/selektivaustauscheranlagen\/\">selective exchangers<\/a> or the <a href=\"https:\/\/decker-vt.de\/en\/products\/ion-exchangers\/\">ion exchanger resins <\/a>contained therein (selective exchanger resins, cation exchanger resins or anion exchanger resins) e.g. from waterworks, municipal sewage treatment plants, electroplating, <a href=\"https:\/\/decker-vt.de\/en\/groundwater-remediation\/\" data-type=\"link\" data-id=\"https:\/\/decker-vt.de\/grundwassersanierung-verfahren-ionenaustauscher\/\">groundwater remediation<\/a> or as final exchangers in an industrial wastewater treatment plant<\/li>\n\n\n\n<li>Delivery emptied of residual water in cartridges (4L \u2013 2000L) or in containers (e.g. 220 liters PE barrel, big bag), dispatch by forwarding agent or by tour.<\/li>\n\n\n\n<li>Specific pre-treatment of the resins<\/li>\n\n\n\n<li>Regeneration using the 2-column principle with separation of anions and cations to avoid cross-contamination or unregenerated interface areas<\/li>\n\n\n\n<li>Durchgehende Sicht auf das Harzbett und etwaige Verunreinigungen<\/li>\n\n\n\n<li>Cleaning, separation and regeneration under various technical conditions such as pressure top\/bottom, negative pressure top\/bottom, swirling compressed air, swirling and rinsing with sterilized DI-water &lt; 0.1 \u00b5S\/cm or city water.<\/li>\n\n\n\n<li>Prevention of carry-over in the system by rinsing steps<\/li>\n\n\n\n<li>Optional proprietary regeneration without external admixture for mixed bed resins (from 400L). Selective resins, anion resins and cation resins are always proprietary regenerations (i.e. no external admixtures) <\/li>\n\n\n\n<li>Regeneration also of UPW mixed bed resins (e.g. Ultra Pure resins or Polisher resins, which are downstream of <a href=\"https:\/\/decker-vt.de\/en\/products\/reverse-osmosis-system-industry\/\">reverse osmosis<\/a> with <a href=\"https:\/\/decker-vt.de\/en\/products\/electrodeionization\/\">electrodeionization (EDI)<\/a> to produce ultrapure water)<\/li>\n\n\n\n<li>Conversion\/conditioning of ion exchangers according to customer requirements in special processes (e.g. cation exchangers in H+, Na+, Ca+, K+ or protonated ammonium form, anion exchangers in OH-, Cl-, NH3- form)<\/li>\n\n\n\n<li>Removal of production-related impurities (e.g. <a href=\"https:\/\/decker-vt.de\/en\/ion-exchanger-fish-odour\/\">odour of fish of the ion exchanger<\/a> ).<\/li>\n\n\n\n<li>Exchange of upstream filter stages such as activated carbon, surfactant\/scavenger resins, gravel\/sand filters.<\/li>\n\n\n\n<li>Special regenerations possible<\/li>\n\n\n\n<li><a href=\"https:\/\/decker-vt.de\/wechsel-ionenaustauscher\/\">Replace ion exchangers<\/a> with new ion exchangers if regeneration is no longer possible.<\/li>\n<\/ul>\n\n\n\n<p>We will be happy to send you a quote for ion exchanger regeneration. <a href=\"https:\/\/decker-vt.de\/en\/contact-form\/\">Contact<\/a> us without obligation.<\/p>\n\n\n\n<p>The service is mostly used in the German-speaking D-A-CH region and northern Italy. We also have English-speaking customers and projects throughout the EU and in some cases outside the EU, e.g. Switzerland and the USA. <\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:var(--wp--preset--spacing--large)\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"1080\" style=\"aspect-ratio: 1920 \/ 1080;\" width=\"1920\" controls src=\"https:\/\/decker-vt.de\/wp-content\/uploads\/2025\/10\/Regeneration-von-Mischbettharzen-in-getrennten-Saeulen-1.mp4\"><\/video><\/figure>\n\n\n\n<div style=\"height:var(--wp--preset--spacing--large)\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Regenerate ion exchangers<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":4663,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"greyd_block_editor_preview":[],"footnotes":""},"class_list":["post-4642","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/pages\/4642","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/comments?post=4642"}],"version-history":[{"count":7,"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/pages\/4642\/revisions"}],"predecessor-version":[{"id":5193,"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/pages\/4642\/revisions\/5193"}],"up":[{"embeddable":true,"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/pages\/4663"}],"wp:attachment":[{"href":"https:\/\/decker-vt.de\/en\/wp-json\/wp\/v2\/media?parent=4642"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}